Thursday, 7 December 2006

Comment on Part List of CVPL

Comments on Part List BG025-00-09-4-013 Rev A
A] Following instruments are to be included in the list:-

1. Temperature Element after convection super heater ( TE 102A ) Refer P&ID BG025-00-09-0-001
2. Open & close limit switches for power cylinders before bed ash cooler :
ZSO 3-01 to 04 & ZSC 3-02 to 05 Refer P&ID BG025-00-09-0-002

3. TE after Air heater (TE 301) Refer P&ID BG025-00-09-0-002
4. The instruments associated with each BFP (PG /TG/PRV) with suitable tagging.
Refer P&ID BG025-00-09-0-009

5. a. PG 101 Refer comments on P&ID BG025-00-10-0-001
b. TG 101 Refer comments on P&ID BG025-00-10-0-001
c. TE 101 Refer comments on P&ID BG025-00-10-0-001
d. PT 903 Refer comments on P&ID BG025-00-10-0-001

6. Temperature gauge after Feed control station.(TG 101) BG025-00-09-0-001
7. Temperature gauge after Economiser (TG 102) BG025-00-09-0-001
8. Temperature element at ESP outlet. (TE 311) BG025-00-09-0-002
9. Pressure switch at common discharge of BFP (PSL 002) BG025-00-09-0-009
10. One no. PSH in furnace (PSH 801) BG025-00-09-0-002


B] Also please include the following instruments as per our comments on P&ID :

1. One more PSH in furnace BG025-00-09-0-002
2. Temperature measurement at sample coolers outlet. BG025-00-09-0-006
3. One redundant level switch at de-areator storage tank. BG025-00-09-0-009

C] In the Part List, the following instruments should be mentioned as CVPL's scope and not "PRDS SUPPLIER" scope).
a) PG 901
b) PG 903
c) TG 901
d) TG 903